Shore to Ship Converters
Transformers
DC~DC Converters
VFD Solutions
Containerized Solutions
Custom Designs

16.7/ 83.3/ 100 Hz Inverter Solutions
Rectifiers
MODBUS Communicated UPS Systems
Transformers

115/ 208V 400Hz Ground Power Units
270Vdc Solutions
28Vdc Engine Starters
Safety Interlock Aircraft Connectors
IP54 Mobile GPUs
Custom Designs and More.

STS Solutions
Dual Source
Multi-Source
Zero Transfer
Priority Selection
Advanced Custom Features and Connectivity

Oil & Gas Industry, Highly Customizable UPS AC & DC UPS Systems
Cathodic Protection Rectifier Systems
Rectifiers and Inverters
IEC 60529
IEC 62040-1, 2, 3
UL, CSA

UPS or Genset Capacity & Performance Testing
Datacenter Simulation
Marine or Military Applications Load Testing
TSINE Load Ultima Series Precise, Over-Engineered Systems and Solutions
IP Rated or Containerized Designs
RLC or DC Load Banks

TSINE LT9000 Series Three Phase UPS | Aa cutting-edge, highly efficient uninterruptible power supply
Dyna-Ion Series Lithium Battery Solution by tsinepower.
Standard 6000 cycles lifetime and 10000 cycles extended cell lifetime.

Containerized Power Systems
Marine, Telecom, Railways, Industrial & BESS - Micro-grid or Utility Operator Industries
Best-in-Class, Plug & Play Ready to Go Designs.
Mobile
Containerized
Centralized
Isolated
ProXtend HP ONLINE UPS
Critical Power Protection, Zero Downtime!
The ProXtend HP UPS presents optimized robust power
protection & performance, highest availability & versatility for
harshest industrial environments, healtcare and datacenter
applications whilst reducing TCO & minimising the time for ROI.
Industrial interconnection converter architecture, the new generation of Static Frequency Converter (SFC) allows the connection of 60 Hz powered equipment to a 50 Hz supply network and 50 Hz powered equipment to a 60 Hz supply network.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
| UPS Rating [Unity Power Factor, kVA=kW, pf.: 1] | Efficiency Levels | ||||||||||||||||||||||
| Rated Power [kVA] | Available in 25 kVA – 1800 kVA | AC~AC Mode, On-line | Up To 97% at 100% Rated Load, 95.5% at 50% Rated Load | ||||||||||||||||||||
| Power Cabinets [kVA] | 150 | 250 | 500 | 180 | 300 | 600 | Eco Mode | > 99% | |||||||||||||||
| Power Modules [kVA] | 25 kVA/ 25 kW; P.f. 1 & 30 kVA/ 30 kW; P.f. 1 | Battery Mode | > 96% | ||||||||||||||||||||
| System Controller & User Interface | Input Characteristics | ||||||||||||||||||||||
| Display Type | 10.4” Touch Colour LCD, LED System Status Indicators & Keyboard | Rated Voltage & Range | 380/ 400/ 415 VAC 3P+N+G -24%~20% 304~478Vac full load; 228V~304Vac, within these tolerances, | ||||||||||||||||||||
| Fail-Safe Design | In the event of a power module failure, the system will continue to operate uninterrupted. | the output load shall decrease l nearly as per the minimum utility voltage. | |||||||||||||||||||||
| Each power module has its own redundant controlled and static bypass, | Rated Frequency & Range | 50/ 60 Hz, 40 ~ 70 Hz | |||||||||||||||||||||
| Zero interruption to the load. | Power Factor | ≥ 0,99 Active Power Factor Correction Circuitry | |||||||||||||||||||||
| Available Languages | 5 Standard – EN-TR-SP-FR-RU | Current Distortion [THDi] | < 3% @ Full Linear Load | ||||||||||||||||||||
| Power Analyser | kVA, kW, PF Info | Power Walk-In | Between 1-30 seconds, with 1 s intervals | ||||||||||||||||||||
| Real Time Clock | Standard with Dynamic Estimation of Back Up Period | ||||||||||||||||||||||
| Event Log | 500 Events with Details & Info, Downloadable via USB-Ethernet | Battery | Back Up Power | |||||||||||||||||||||
| Smart Event Notification & Scheduled Shutdown for Servers | Controlled Shutdown. Alerts sent directly to email in the event of a malfunction (Standard | Rated Voltage [DC] | ±240VDC, 32 to 44 * 12VDC (Adjustable) VRLA AGM Sealed Lead Acid, Ge | ||||||||||||||||||||
| up to 10 users) Text message alerts sent directly to the user in the event of a malfunction (Optional) | DC Input Range | Final Discharge Voltage can be 1.65Vdc or 1.7Vdc | |||||||||||||||||||||
| Scheduled Automatic Shutdown of Servers on Battery Mode (Standard) | Ai-BM | Manual & Scheduled Battery Test, Scheduled Automatic Shutdown of Servers on Battery Mode, | |||||||||||||||||||||
| On-Screen Parameters | Load Bar-Graph, 3 Phase Voltages & Currents & Frequencies, Battery Voltage, Status Info for | (Optional) Real Time Dynamic Remaining Back Up Calculation, | |||||||||||||||||||||
| Each Power Module, Static Bypass Module Parameters & Status Info, Battery Temperature | Modular Hot-Swap Battery | Optional | |||||||||||||||||||||
| Alarms | AC Failure, DC Failure, UPS Module(s) Failure, Bypass Mode, Battery Test Failure, Over Temperature, | Charging Capacity | 6A for Each 20 kVA Module, 9A for Each 30 kVA Module | ||||||||||||||||||||
| Overload Operation, More Than 60 Other Alarms Listed in User Manual, Audible Alarms | Operating Temperature | 25ºC, Temperature Compensated 4 Stage Charging | |||||||||||||||||||||
| SNMP-Remote Montoring (MS Windows), TCP/IP, Monitoring Over Web Browser, Hot swappable | |||||||||||||||||||||||
| Connectivity | smart slot card, RJ -45 interface port, USB, RS232, RS485, MODBUS, Optional GPRS/SMS Wireless, | Output Characteristics | |||||||||||||||||||||
| Programmable Dry Contacts | Rated Voltage & Accuracy | 380/ 400/ 415 VAC 3P+N ± 1% for Static Load, for Dynamic Load (Step Load) : ± 5% | |||||||||||||||||||||
| Communication with Power Modules | Serial, Isolated | Rated f. & Accuracy | 50/ 60 Hz (Selectable), ±1% ( Synchronized to Mains, Adjustable up to ±5%), | ||||||||||||||||||||
| Dry Contacts | 3 Programmable Dry Contacts for Input, 11 pcs Parameters, 4 Programmable Dry Contacts for | ±0,1% ( Free Running Mode, Selectable) | |||||||||||||||||||||
| Output, 15 pcs Parameters, 19 Dry Contacts, EPO Outputs in Total | WaveForm | Pure Sine Wave – Sinusoidal | |||||||||||||||||||||
| Voltage Distortion [THDv] | < 1% (Linear Load), < 4% (Non-Linear Load) according to IEC/EN62040-3 | ||||||||||||||||||||||
| General Characteristics | Crest Factor | 3:1 | |||||||||||||||||||||
| MTBF/ MTTR | Over 600000 Hours | Unbalanced Load & Acceptable Load PF | Compatible with Operation on 100% Unbalanced Load 0.3 to 1 | ||||||||||||||||||||
| UPS Type & Technology | VFI-SS-111 | Online Double Conversion, Three Level Technology | Overload Operation | 60 minutes @ 110% Rated Load, 10 minutes @ 125% Rated Load 1 minutes @ 150% Rated Load | ||||||||||||||||||||
| DSP Microprocessor Controlled, Hot-Swap Modular Architecture | Switches to Bypass over 150% Rated Load | ||||||||||||||||||||||
| Isolation Transformer | STANDARD For Flex-T Series | ||||||||||||||||||||||
| 62040-3 | COMPATIBLE | Ambient Characteristics | |||||||||||||||||||||
| Power Factor | 0,9 or 1 kVA=kW Unity Power Factor | Ambient Temperature | OPERATING TEMPERATURE RANGE -10ºC – 40ºC | ||||||||||||||||||||
| True Redundancy | N+X, N+1 Redundancy, True Modular UPS Topology | RECOMMENDED OPERATING TEMPERATURE 15ºC – 25ºC | |||||||||||||||||||||
| Parallel Configuration [N+1] | Up to 3 Power Cabinets and 1800 Kw | STORAGE TEMPERATURE -30ºC ~ 70ºC | |||||||||||||||||||||
| Input Power Limiting, Phase Reversal, Power Module Over Temperature, Over Current, | Altitute/ Relative Humidity | < 1000m above sea level without derating of output power, | |||||||||||||||||||||
| Standard Protection Features | High Temperature Alert, Smart Short Circuit, Regenerative Load, Current Limiting, Charging Current | output power is derated 1% per 100m from 1000 to 2000m | |||||||||||||||||||||
| Limiting, Temperature Compensated Charging, Emergency Power Off (EPO). | Noise | < 65dB @ 100% load, 62dB @ 45% load | |||||||||||||||||||||
| Operating Conditions | 20 ºC, <2400m Above Sea Level, <45% to 55% RH for Best Performance | ||||||||||||||||||||||
| Cooling/ Isolation | Forced Air Cooling via Redundant Fans – Smart Fan Speed | Standards & Certifications | |||||||||||||||||||||
| Ma ntenance Bypass | STANDARD | Safety | EN 62040-1, EN60950, CE Mark | ||||||||||||||||||||
| Material [Casing]/ Colour | RAL 7021, BLACK | EMC | EN 62040-2 Class C2, CE Mark – Electro-magnetic Compability | ||||||||||||||||||||
| Cable Entry | REAR/ FRONT BOTTOM | Performance | EN 62040-3 (VFI-SS111), CE Mark | ||||||||||||||||||||
| Operation Modes | Normal Mode: The input rectifier & output inverter operates in an on-line status to continuously supply power to the critical load. | Quality Management | ISO 9001:2015, TUV, CE Mark | ||||||||||||||||||||
| Battery Mode: Upon failure of the AC input source, the critical load is being continued to be supplied by the inverter, which derives its power from the battery system without any interruption. | |||||||||||||||||||||||
| Recharge: Upon restoration of the AC input source, the UPS simultaneously recharges the battery and provides regulated power to the critical load. | Optional Features & Accessories | ||||||||||||||||||||||
| Static Bypass: The static bypass shall be used to provide transfer of critical load from the Inverter output to the bypass source. | Parallel Redundancy | Horizantal Power Scaling, Optional | |||||||||||||||||||||
| Internal Manual/ Mechanical Bypass: The UPS is equipped with an internal, make before break, bypass switch. | Hot-Swappable Battery | Optional | |||||||||||||||||||||
| Extended Runtime | Optional | ||||||||||||||||||||||
| M. Bypass Cab net | Optional | ||||||||||||||||||||||
| Custom Input Voltage | Optional | ||||||||||||||||||||||
| IP Classified Enclosure | Standard IP21, Optional up to IP 66 | ||||||||||||||||||||||
Tab Content
We are TSINE, global power solution expert, expert with its innovative, industry leading end-to-end product & service solutions and vast experience in power quality industry.
TSINE’ s journey starts 20+ years ago with 3 electrical and electronics engineers specialized in power conversion design and today, in 2015, the company is a global leader in power quality industry all over the world.
Today, TSINE’s engineers and employees is here at TSINE with their entrepreneurial spirit to create innovative, end-to-end product & service solutions. Pure engineering & dynamic R&D, absolute customer satisfaction are the cores that TSINE and TSINE’ s dedicated team offers. TSINE is committed to creating and maintaining powerful partner relationships built on honesty, professionalism and excellence.
| Form Factor | |
|---|---|
| Input Voltage | 190/ 200/ 208/ 220 3P+N, 208/ 220/ 230/ 240 3P+N, 360/ 380/ 400/ 415/ 440Vac 3P+N |
| Output Power Factor | |
| Output Voltage | 100/ 110/ 115/ 120/ 127VAC Single Phase, 190/ 200/ 208/ 220VAC Three Phase, 200/ 208/ 220/ 230/ 240/ 277VAC Single Phase, 380/ 400/ 415VAC Three Phase, 440/ 480VAC Three Phase |
| Power Capacity | 10 – 120 kVA, Three Phase, 150-400 kVA, Three Phase, 20 – 80 kVA, Single Phase Output, 5 – 20 kVA, Single Phase, 500 – 1200 kVA, Three Phase, 600 VA – 3 Kva, Single Phase |
| UPS Type | |
| Efficiency | AC~AC Efficiency is Up To 95% |