Proven, Robust Performance in Challenging Environments & Loads
ProXtend HP EU UPS is a high frequency, double conversion uninterruptible power supply system for three phase loads & systems. The UPS has in-built output isolation transformer and has also 3Phase Input, Single Phase Output and North American 208V L-L versions available in standard production.
IGBT Rectifier & Inverter design with output isolation transformer is robust and reliable and preferred mainly by the Industrial clients, Datacenters, IT companies, large server systems, healthcare facilities and CT, MRI applications, facility loads in buildings, government facilities, private sector headquarters and for the loads & systems where the utility power has frequent fluctuations such Africa, Middle East, Bangladesh, Vietnam...etc.
The UPS stays ahead of the game with its galvanic isolation, best in class AC~AC double conversion efficiency as up to 94.5% and high overload capacity.
Total input current harmonics distortion becomes less than 3%
Output power factor is 0.9 and 1, Unity Power Factor, kVA=kW and total voltage harmonics distortion is less than 1%,
As a result; The ProXtend HP EU, Made in Italy UPS presents optimized power protection & performance, highest availability & versatility for harshest industrial environments, healthcare and datacenter applications.
ProXtend HP EU, with TSINE expertise behind and premium components inside, is engineered to meet the needs of demanding environments & businesses worldwide.
High AC~AC efficiency levels up to 94.5%
High battery conversion, inverter efficiency as 96.5%
Zero Effect on UtilityZero Effect on Utility with Active Power Factor Correction at Input, pf is ≥ 0.99
Low total harmonic distortion for input current as ≤ 4%
Adaptability & ProtectionCompatible with the toughest application requirements with its super efficient IGBT Rectifier without sacraficing reliability.
Fault tolerant design allows the UPS both protect the connected load and itself from mechanical & electrical forces.
Robust, easy to operate UPS has excellent overload and short circuit capability, superior dynamic response and is easy to maintain.
High Power Density, Minimum FootprintCompact, easy and ready to install dimensions, minimized footprint, ease to move & locate inside buildings,
160 kVA footprint is only 0,87 m2 (Module IGBT rectifier and inverter), Maximum single unit capacity is 800 kVA in 1,74 m2
Up to 40 kVA, Inbuilt batteries saves from space.
Maximized AvailabilityThe UPS ProXtend HE is designed for maximized availability and uptime.
Minimized Service and Repair Times, Maximum Time to Repair, MTTR; Maximized Mean Time Between Failures, MTBF, times
Since a datacenter’ s availability is scaled as 99.99%, Our UPS Systems offers the similar.
Lower CAPEX | Capital ExpendituresThanks to Lower THDi and Active PFC at Input Side, Cost savings on Low Voltage Installation in UpStream The UPS
Reduced installation and operation costs, minimized footprint, minimized UPS/Electrical Room Requirements.
Lower OPEX | Operational ExpendituresOperational expenditure is optimized with a complete and cost effective life cycle.
The high efficiency of the complete UPS (AC/AC), as well as of the inverter part (DC/AC), even at partial load, helps optimizing both HVAC system and battery sizing.
Less maintenance needs, advanced battery management which leads extended battery lifetime and extended lifetimes for lifed items means long replacement times and avoiding repeating costs.
Fast RoI | Return of Investment
The Result: Reduced Total Cost of Ownership & Fast Return of Investment
Thanks to Max. Availability and Max. Uptime for The Businesses, Minimized Downtimes.
Easy & Fast Serviceability, Fast Dynamic Solutions to On-Site Problems
Robust, Reliable Operation, Proven Track Record and Use
Compact, highly-efficient, cutting-edge technology with built-in features to adapt to diverse environments and requirements.
IGBT Rectifier/ IGBT Inverter, Double Conversion Architecture, Available with Various Global Voltages
Seamless transfer between sources, high generator compability
High efficiency rates as up to 94%, even at partial load
Small footprint, high power density
Fault-tolerant, over-engineered design, DSP ultra high speed control architecture
High output short-circuit clearance capability
High output short-circuit clearance capability
Prolonged battery lifetime, budget -friendly lifetime.
Reliable Redundant parallel operation
High communication and connectivity capabilities
Options for Enclosure IP Classifications, Isolation Transformers,
Best Suited for
Facilities, Mixed Loads Use
Industrial Loads & Systems
Medium & Large Sized Enterprises
Healthcare Facilities, Diagnostics and Medical Imaging Systems, CTs, MRIs, Angiography Devices
Financial Institutions, Banks, Banks Headquarters
Buildings of Government, Institutions & Organizations
| UPS Rating [Unity Power Factor, kVA=kW, pf.: 1] | Efficiency Levels | ||||||||||||||||||||||
| Rated Power [kVA] | Available in 25 kVA – 1800 kVA | AC~AC Mode, On-line | Up To 97% at 100% Rated Load, 95.5% at 50% Rated Load | ||||||||||||||||||||
| Power Cabinets [kVA] | 150 | 250 | 500 | 180 | 300 | 600 | Eco Mode | > 99% | |||||||||||||||
| Power Modules [kVA] | 25 kVA/ 25 kW; P.f. 1 & 30 kVA/ 30 kW; P.f. 1 | Battery Mode | > 96% | ||||||||||||||||||||
| System Controller & User Interface | Input Characteristics | ||||||||||||||||||||||
| Display Type | 10.4” Touch Colour LCD, LED System Status Indicators & Keyboard | Rated Voltage & Range | 380/ 400/ 415 VAC 3P+N+G -24%~20% 304~478Vac full load; 228V~304Vac, within these tolerances, | ||||||||||||||||||||
| Fail-Safe Design | In the event of a power module failure, the system will continue to operate uninterrupted. | the output load shall decrease l nearly as per the minimum utility voltage. | |||||||||||||||||||||
| Each power module has its own redundant controlled and static bypass, | Rated Frequency & Range | 50/ 60 Hz, 40 ~ 70 Hz | |||||||||||||||||||||
| Zero interruption to the load. | Power Factor | ≥ 0,99 Active Power Factor Correction Circuitry | |||||||||||||||||||||
| Available Languages | 5 Standard – EN-TR-SP-FR-RU | Current Distortion [THDi] | < 3% @ Full Linear Load | ||||||||||||||||||||
| Power Analyser | kVA, kW, PF Info | Power Walk-In | Between 1-30 seconds, with 1 s intervals | ||||||||||||||||||||
| Real Time Clock | Standard with Dynamic Estimation of Back Up Period | ||||||||||||||||||||||
| Event Log | 500 Events with Details & Info, Downloadable via USB-Ethernet | Battery | Back Up Power | |||||||||||||||||||||
| Smart Event Notification & Scheduled Shutdown for Servers | Controlled Shutdown. Alerts sent directly to email in the event of a malfunction (Standard | Rated Voltage [DC] | ±240VDC, 32 to 44 * 12VDC (Adjustable) VRLA AGM Sealed Lead Acid, Ge | ||||||||||||||||||||
| up to 10 users) Text message alerts sent directly to the user in the event of a malfunction (Optional) | DC Input Range | Final Discharge Voltage can be 1.65Vdc or 1.7Vdc | |||||||||||||||||||||
| Scheduled Automatic Shutdown of Servers on Battery Mode (Standard) | Ai-BM | Manual & Scheduled Battery Test, Scheduled Automatic Shutdown of Servers on Battery Mode, | |||||||||||||||||||||
| On-Screen Parameters | Load Bar-Graph, 3 Phase Voltages & Currents & Frequencies, Battery Voltage, Status Info for | (Optional) Real Time Dynamic Remaining Back Up Calculation, | |||||||||||||||||||||
| Each Power Module, Static Bypass Module Parameters & Status Info, Battery Temperature | Modular Hot-Swap Battery | Optional | |||||||||||||||||||||
| Alarms | AC Failure, DC Failure, UPS Module(s) Failure, Bypass Mode, Battery Test Failure, Over Temperature, | Charging Capacity | 6A for Each 20 kVA Module, 9A for Each 30 kVA Module | ||||||||||||||||||||
| Overload Operation, More Than 60 Other Alarms Listed in User Manual, Audible Alarms | Operating Temperature | 25ºC, Temperature Compensated 4 Stage Charging | |||||||||||||||||||||
| SNMP-Remote Montoring (MS Windows), TCP/IP, Monitoring Over Web Browser, Hot swappable | |||||||||||||||||||||||
| Connectivity | smart slot card, RJ -45 interface port, USB, RS232, RS485, MODBUS, Optional GPRS/SMS Wireless, | Output Characteristics | |||||||||||||||||||||
| Programmable Dry Contacts | Rated Voltage & Accuracy | 380/ 400/ 415 VAC 3P+N ± 1% for Static Load, for Dynamic Load (Step Load) : ± 5% | |||||||||||||||||||||
| Communication with Power Modules | Serial, Isolated | Rated f. & Accuracy | 50/ 60 Hz (Selectable), ±1% ( Synchronized to Mains, Adjustable up to ±5%), | ||||||||||||||||||||
| Dry Contacts | 3 Programmable Dry Contacts for Input, 11 pcs Parameters, 4 Programmable Dry Contacts for | ±0,1% ( Free Running Mode, Selectable) | |||||||||||||||||||||
| Output, 15 pcs Parameters, 19 Dry Contacts, EPO Outputs in Total | WaveForm | Pure Sine Wave – Sinusoidal | |||||||||||||||||||||
| Voltage Distortion [THDv] | < 1% (Linear Load), < 4% (Non-Linear Load) according to IEC/EN62040-3 | ||||||||||||||||||||||
| General Characteristics | Crest Factor | 3:1 | |||||||||||||||||||||
| MTBF/ MTTR | Over 600000 Hours | Unbalanced Load & Acceptable Load PF | Compatible with Operation on 100% Unbalanced Load 0.3 to 1 | ||||||||||||||||||||
| UPS Type & Technology | VFI-SS-111 | Online Double Conversion, Three Level Technology | Overload Operation | 60 minutes @ 110% Rated Load, 10 minutes @ 125% Rated Load 1 minutes @ 150% Rated Load | ||||||||||||||||||||
| DSP Microprocessor Controlled, Hot-Swap Modular Architecture | Switches to Bypass over 150% Rated Load | ||||||||||||||||||||||
| Isolation Transformer | STANDARD For Flex-T Series | ||||||||||||||||||||||
| 62040-3 | COMPATIBLE | Ambient Characteristics | |||||||||||||||||||||
| Power Factor | 0,9 or 1 kVA=kW Unity Power Factor | Ambient Temperature | OPERATING TEMPERATURE RANGE -10ºC – 40ºC | ||||||||||||||||||||
| True Redundancy | N+X, N+1 Redundancy, True Modular UPS Topology | RECOMMENDED OPERATING TEMPERATURE 15ºC – 25ºC | |||||||||||||||||||||
| Parallel Configuration [N+1] | Up to 3 Power Cabinets and 1800 Kw | STORAGE TEMPERATURE -30ºC ~ 70ºC | |||||||||||||||||||||
| Input Power Limiting, Phase Reversal, Power Module Over Temperature, Over Current, | Altitute/ Relative Humidity | < 1000m above sea level without derating of output power, | |||||||||||||||||||||
| Standard Protection Features | High Temperature Alert, Smart Short Circuit, Regenerative Load, Current Limiting, Charging Current | output power is derated 1% per 100m from 1000 to 2000m | |||||||||||||||||||||
| Limiting, Temperature Compensated Charging, Emergency Power Off (EPO). | Noise | < 65dB @ 100% load, 62dB @ 45% load | |||||||||||||||||||||
| Operating Conditions | 20 ºC, <2400m Above Sea Level, <45% to 55% RH for Best Performance | ||||||||||||||||||||||
| Cooling/ Isolation | Forced Air Cooling via Redundant Fans – Smart Fan Speed | Standards & Certifications | |||||||||||||||||||||
| Ma ntenance Bypass | STANDARD | Safety | EN 62040-1, EN60950, CE Mark | ||||||||||||||||||||
| Material [Casing]/ Colour | RAL 7021, BLACK | EMC | EN 62040-2 Class C2, CE Mark – Electro-magnetic Compability | ||||||||||||||||||||
| Cable Entry | REAR/ FRONT BOTTOM | Performance | EN 62040-3 (VFI-SS111), CE Mark | ||||||||||||||||||||
| Operation Modes | Normal Mode: The input rectifier & output inverter operates in an on-line status to continuously supply power to the critical load. | Quality Management | ISO 9001:2015, TUV, CE Mark | ||||||||||||||||||||
| Battery Mode: Upon failure of the AC input source, the critical load is being continued to be supplied by the inverter, which derives its power from the battery system without any interruption. | |||||||||||||||||||||||
| Recharge: Upon restoration of the AC input source, the UPS simultaneously recharges the battery and provides regulated power to the critical load. | Optional Features & Accessories | ||||||||||||||||||||||
| Static Bypass: The static bypass shall be used to provide transfer of critical load from the Inverter output to the bypass source. | Parallel Redundancy | Horizantal Power Scaling, Optional | |||||||||||||||||||||
| Internal Manual/ Mechanical Bypass: The UPS is equipped with an internal, make before break, bypass switch. | Hot-Swappable Battery | Optional | |||||||||||||||||||||
| Extended Runtime | Optional | ||||||||||||||||||||||
| M. Bypass Cab net | Optional | ||||||||||||||||||||||
| Custom Input Voltage | Optional | ||||||||||||||||||||||
| IP Classified Enclosure | Standard IP21, Optional up to IP 66 | ||||||||||||||||||||||