• United States
    • Türkiye
    • Americas
    • EMEA
    • North America
    • CIS Region
    • Russian Federation
    • United Kingdom
    • Philipinnes
  • Quick Access Links
    • Industrial UPS Systems
    • CT & MRI UPS, Power Systems for Healthcare
    • Voltage Regulators
    • Modular UPS
    • Industrial AC & DC Power Solutions
    • UPS Systems for Manufacturing Industries

Contact

  • info@tsinepower.com
  • +905058586504
  • Products & Services
    airport ups system

    Critical Power

    Static Transfer Switches (STS)

    Uninterruptible Power Supplies (UPS)

    Small & Medium Size Businesses

    Data Center and Facility 3 Phase UPS

    Modular UPS Systems

    UPS Systems for Manufacturing Industries

    UPS Systems for CT, MRI and Other Healthcare Applications

    Special Applications

    DC Power Systems

    Central Battery Systems | Emergency Lighting

    Industrial Inverters | DC ~ AC

    Commercial Inverter Systems | DC ~ AC

    Solar Inverters, Hybrid Systems

    Power Conditioning

    Voltage Regulators

    Servo/ Electrodynamic Voltage Stabilizers

    Static/ Solid State Voltage Stabilizers

    Industrial Rectifiers

    Battery Chargers

    DC Power Supplies

    Battery Regeneration

    Electro-Chemical Industries       Plating, Electroplating, Anodizing, Coloring, Electrolysis, Surface Treatment, Water Treatment, Rare Earth Minerals Smelting

    Application Special Power Conversion Systems

    Aviation Power, GPU Systems       400 Hz Frequency Converters

    Industrial, & Railways Frequency Converter Solutions 16.7/ 25/ 50/ 60/ 67/ 83.3/ 100/ 400 Hz

    Motor Control | AC Drive | VFD

    DC ~ DC Converters

    AC ~AC Voltage & Frequency Converters

    HV Panels, Main DB & Genset Synch Panels

    Reactive Power Compensation, Capacitor Banks

    marine shore to ship power

    Containerized Solutions

    Containerized UPS Systems

    Marine Converters | Shore to Shp Power, 440V 60Hz

    Load Banks, AC & DC

    Oil & Gas Industries

    Heavy Duty Oil & Gas AC and DC UPS Systems

    Cathodic Protection Rectifiers

    Lithium UPS Systems

    Industrial Batteries

    Transformers

    Transformers

    Reactors & Inductors

  • Solutions
    marine shore to ship power

    Marine & Maritime

    Shore to Ship Converters
    Transformers
    DC~DC Converters
    VFD Solutions
    Containerized Solutions
    Custom Designs

    Railways

    16.7/ 83.3/ 100 Hz Inverter Solutions
    Rectifiers
    MODBUS Communicated UPS Systems
    Transformers

    Aviation Power

    115/ 208V 400Hz Ground Power Units
    270Vdc Solutions
    28Vdc Engine Starters
    Safety Interlock Aircraft Connectors
    IP54 Mobile GPUs
    Custom Designs and More.

    static transfer switch sts

    Static Transfer Switches

    STS Solutions
    Dual Source
    Multi-Source
    Zero Transfer
    Priority Selection
    Advanced Custom Features and Connectivity

    oil gas ups, rectifier, cathodic protection

    Oil & Gas Industries

    Oil & Gas Industry, Highly Customizable UPS AC & DC UPS Systems
    Cathodic Protection Rectifier Systems
    Rectifiers and Inverters
    IEC 60529
    IEC 62040-1, 2, 3
    UL, CSA

    Load Banks

    UPS or Genset Capacity & Performance Testing
    Datacenter Simulation
    Marine or Military Applications Load Testing
    TSINE Load Ultima Series Precise, Over-Engineered Systems and Solutions
    IP Rated or Containerized Designs
    RLC or DC Load Banks

    Lithium UPS Solutions


    TSINE LT9000 Series Three Phase UPS | Aa cutting-edge, highly efficient uninterruptible power supply
    Dyna-Ion Series Lithium Battery Solution by tsinepower.
    Standard 6000 cycles lifetime and 10000 cycles extended cell lifetime.

    Containerized
    Solutions





    Containerized Power Systems
    Marine, Telecom, Railways, Industrial & BESS - Micro-grid or Utility Operator Industries
    Best-in-Class, Plug & Play Ready to Go Designs.
    Mobile

    Containerized
    Centralized
    Isolated

  • Support
  • About TSINE

    About TSINE

    Mission & Vision

    Global Presence

    Careers

  • Contact

Related products

NetXtend HP UPS

Hot-Swap Modular UPS | NetXtend Flex N9000

ProXtend HE UPS

ProXtend Industrial

Legacy Transformer Based, Low Frequency, SCR Rectifier & IGBT Inverter UPS | ProXtend Industrial

Home / Uninterruptible Power Supply | UPS / deneme

deneme

Awaiting product image
Product Snapshot
Features & Benefits
Technical Specifications
Documents & Downloads
Product Snapshot

Industrial interconnection converter architecture, the new generation of Static Frequency Converter (SFC) allows the connection of 60 Hz powered equipment to a 50 Hz supply network and 50 Hz powered equipment to a 60 Hz supply network.

Features & Benefits

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Technical Specifications
UPS Rating [Unity Power Factor, kVA=kW, pf.: 1]Efficiency Levels
Rated Power [kVA]Available in 25 kVA – 1800 kVAAC~AC Mode, On-lineUp To 97% at 100% Rated Load, 95.5% at 50% Rated Load
Power Cabinets [kVA]150250500180300600Eco Mode> 99%
Power Modules [kVA] 25 kVA/ 25 kW; P.f. 1 & 30 kVA/ 30 kW; P.f. 1Battery Mode> 96%
System Controller & User InterfaceInput Characteristics
Display Type10.4” Touch Colour LCD, LED System Status Indicators & KeyboardRated Voltage & Range380/ 400/ 415 VAC 3P+N+G -24%~20% 304~478Vac full load; 228V~304Vac, within these tolerances,
Fail-Safe DesignIn the event of a power module failure, the system will continue to operate uninterrupted. the output load shall decrease l nearly as per the minimum utility voltage.
Each power module has its own redundant controlled and static bypass, Rated Frequency & Range50/ 60 Hz, 40 ~ 70 Hz
Zero interruption to the load.Power Factor≥ 0,99 Active Power Factor Correction Circuitry
Available Languages5 Standard – EN-TR-SP-FR-RUCurrent Distortion [THDi]< 3% @ Full Linear Load
Power AnalyserkVA, kW, PF InfoPower Walk-InBetween 1-30 seconds, with 1 s intervals
Real Time ClockStandard with Dynamic Estimation of Back Up Period
Event Log500 Events with Details & Info, Downloadable via USB-EthernetBattery | Back Up Power
Smart Event Notification
& Scheduled Shutdown for Servers
Controlled Shutdown. Alerts sent directly to email in the event of a malfunction (StandardRated Voltage [DC]±240VDC, 32 to 44 * 12VDC (Adjustable) VRLA AGM Sealed Lead Acid, Ge
up to 10 users) Text message alerts sent directly to the user in the event of a malfunction (Optional) DC Input RangeFinal Discharge Voltage can be 1.65Vdc or 1.7Vdc
Scheduled Automatic Shutdown of Servers on Battery Mode (Standard)Ai-BM Manual & Scheduled Battery Test, Scheduled Automatic Shutdown of Servers on Battery Mode,
On-Screen ParametersLoad Bar-Graph, 3 Phase Voltages & Currents & Frequencies, Battery Voltage, Status Info for (Optional) Real Time Dynamic Remaining Back Up Calculation,
Each Power Module, Static Bypass Module Parameters & Status Info, Battery TemperatureModular Hot-Swap BatteryOptional
AlarmsAC Failure, DC Failure, UPS Module(s) Failure, Bypass Mode, Battery Test Failure, Over Temperature, Charging Capacity 6A for Each 20 kVA Module, 9A for Each 30 kVA Module
Overload Operation, More Than 60 Other Alarms Listed in User Manual, Audible AlarmsOperating Temperature25ºC, Temperature Compensated 4 Stage Charging
SNMP-Remote Montoring (MS Windows), TCP/IP, Monitoring Over Web Browser, Hot swappable
Connectivitysmart slot card, RJ -45 interface port, USB, RS232, RS485, MODBUS, Optional GPRS/SMS Wireless,Output Characteristics
Programmable Dry ContactsRated Voltage & Accuracy380/ 400/ 415 VAC 3P+N ± 1% for Static Load, for Dynamic Load (Step Load) : ± 5%
Communication with Power ModulesSerial, IsolatedRated f. & Accuracy50/ 60 Hz (Selectable), ±1% ( Synchronized to Mains, Adjustable up to ±5%),
Dry Contacts3 Programmable Dry Contacts for Input, 11 pcs Parameters, 4 Programmable Dry Contacts for ±0,1% ( Free Running Mode, Selectable)
Output, 15 pcs Parameters, 19 Dry Contacts, EPO Outputs in TotalWaveFormPure Sine Wave – Sinusoidal
Voltage Distortion [THDv]< 1% (Linear Load), < 4% (Non-Linear Load) according to IEC/EN62040-3
General CharacteristicsCrest Factor3:1
MTBF/ MTTR Over 600000 HoursUnbalanced Load & Acceptable Load PFCompatible with Operation on 100% Unbalanced Load 0.3 to 1
UPS Type & Technology VFI-SS-111 | Online Double Conversion, Three Level TechnologyOverload Operation60 minutes @ 110% Rated Load, 10 minutes @ 125% Rated Load 1 minutes @ 150% Rated Load
DSP Microprocessor Controlled, Hot-Swap Modular ArchitectureSwitches to Bypass over 150% Rated Load
Isolation TransformerSTANDARD For Flex-T Series
62040-3COMPATIBLEAmbient Characteristics
Power Factor 0,9 or 1 kVA=kW Unity Power FactorAmbient TemperatureOPERATING TEMPERATURE RANGE -10ºC – 40ºC
True Redundancy N+X, N+1 Redundancy, True Modular UPS TopologyRECOMMENDED OPERATING TEMPERATURE 15ºC – 25ºC
Parallel Configuration [N+1]Up to 3 Power Cabinets and 1800 KwSTORAGE TEMPERATURE -30ºC ~ 70ºC
Input Power Limiting, Phase Reversal, Power Module Over Temperature, Over Current, Altitute/ Relative Humidity< 1000m above sea level without derating of output power,
Standard Protection FeaturesHigh Temperature Alert, Smart Short Circuit, Regenerative Load, Current Limiting, Charging Currentoutput power is derated 1% per 100m from 1000 to 2000m
Limiting, Temperature Compensated Charging, Emergency Power Off (EPO).Noise< 65dB @ 100% load, 62dB @ 45% load
Operating Conditions 20 ºC, <2400m Above Sea Level, <45% to 55% RH for Best Performance
Cooling/ Isolation Forced Air Cooling via Redundant Fans – Smart Fan SpeedStandards & Certifications
Ma ntenance Bypass STANDARDSafetyEN 62040-1, EN60950, CE Mark
Material [Casing]/ Colour RAL 7021, BLACKEMCEN 62040-2 Class C2, CE Mark – Electro-magnetic Compability
Cable Entry REAR/ FRONT BOTTOMPerformance EN 62040-3 (VFI-SS111), CE Mark
Operation ModesNormal Mode: The input rectifier & output inverter operates in an on-line status to continuously supply power to the critical load.Quality ManagementISO 9001:2015, TUV, CE Mark
Battery Mode: Upon failure of the AC input source, the critical load is being continued to be supplied by the inverter, which derives its power from the battery system without any interruption.
Recharge: Upon restoration of the AC input source, the UPS simultaneously recharges the battery and provides regulated power to the critical load.Optional Features & Accessories
Static Bypass: The static bypass shall be used to provide transfer of critical load from the Inverter output to the bypass source.Parallel RedundancyHorizantal Power Scaling, Optional
Internal Manual/ Mechanical Bypass: The UPS is equipped with an internal, make before break, bypass switch.Hot-Swappable BatteryOptional
Extended RuntimeOptional
M. Bypass Cab netOptional
Custom Input VoltageOptional
IP Classified EnclosureStandard IP21, Optional up to IP 66
Documents & Downloads

Tab Content

  • Documents & Downloads
  • Product Snapshop, Features & Benefits
  • Technical Specifications